COLD PLUNGE CHILLER UNIT INSTRUCTION MANUAL

Parameter Modification

Press and hold (set key) for 5 seconds. When the nixie tube displays PD, press (up key) or down key) to enter the correct password, and then press (set key) to confirm. After the password is correct, you can enter the menu. Long press the SET key till it displays PD for parameter modifications, press UP or DOWN to enter the password and press SET to confirm.

Safety Warning

  • .Due to transportation safety regulations, the machine you received may not contain freon. Machine needs to be filled with freon before use. Running without freon can seriously damage the machine!
  • .Freon re-filling and future maintenance must be performed by professional and technical person who comply with local installation and maintenance codes and rules and have rich installation and maintenance experience, Please refer to the machine name plate for the amount of freon re-filling.
  • .Sharp edges and coil surfaces are harmful and should be avoided
  • .lf unit is not powered on for a long time, in the environment of s0C, the water in the heat exchanger and water tank may freeze which resulting in cracking. lf not in use, please drain water.
  • .Power switch should be set in 1.4 meters or above where children can not reach.
CodeMenu ContentRangeDefaultCompany
F01Temperature Return Difference0.3~102
F02Temperature Correction-5~50
F03Start Delay 1~53min
F04Menu Password0~25595
F05Defrost Time1~453min
F06Defrost Cycle10~24060min
F070: Celcius/1:Fahrenheit
F08Working ModeHC~CHC
F09Heating Mode0~11min
F10Detection port shieldingOFF~ONOFF
F11Upper Temperature Limit-19~7040
F12Lower Temperature Limit70~190
F13Current Overload Protection0~258A
F14Overload Delay Protection2~2910sec
F15AbnormalTemperature Alarm0~80
F16O3/UV Sterilization0~18060  min

 

Indicator Light

IconNameHengliang RepresentativeExtinguish representsFlashing Representative
 Refrigeration lampCoolingStop RefrigerationCompressors delaying
constant temperatureTarget Temperature ReachedNot at Target Temperature
Heating lampHeating in ProgressStop HeatingCompressor is Delaying
Defrost lampDefrostingStop DefrostingCompressor is Delaying
Networking lampConnected to the InternetNot Connected to the InternetIn Distribution Network

 

 

 

Overall Appearance And Size

Sterilizer

O-zone/UV

1.Must be turned off when taking a cold plunge.

2.Turns off autometically after 60mins of working.Can be turned back on manually.

3.Service life is around 3000 hours.

4.Due to the corrosiveness of ozone,please take note to replace any rubber hoses.

 

Full Range of Product Models And Sizes

MODEL9000BTU12000BTU18000BTU
Setting temperature range3~40°C(Factory default 3C)
FilterationFolded paper 30um
O-zone/UV30~50mg/h
Inflow/Outflow sizeDN15 Inner Thread
Water pump typeNon-self priming
Note: the above specifications may subject to change without prior notice.

Filteration

cold_plunge_chiller_filter

Suggested to replace filter every 3 months.

1.Use a wrench to unscrew the filter bottle:

2.Remove the old filterand replace with a new one:

3.Cap the bottle and make sure it’s fastened.

4. Check for water leakage before the replacements complete.

Electric Control lnstruction

Front of Display

Cold plunge Control Panel

 

IconNameDescription
Power KeyPress to power on/off the unit.
Set KeyPress once to adjust the setting temperature. Press and long hold to enter the menu to modify the operating parameters.
Up KeyUsed to adjust parameters upward.
Down keyUsed to adiust parameters downward.
SterilizerUsed to turn on/off the O3 /UV output

Installation Precaution

Warning: there is a built in non-self priming water pump at the filter ensure the filter is pre-filled with water before starting each time!

 

NEVER RUN THE PUMP DRY

CORRUGATED HOSE PROHIBITED

HOSES LENGTH <1.5M/5FT
INNER DIAMTER: DN15 OR ABOVE